نتایج جستجو برای: PCXMC Software

تعداد نتایج: 437272  

2018
Eun-Kyung Kim Won-Jeong Han Jin-Woo Choi Bulgan Battulga

Purpose To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods An Alphard VEGA CBCT scanner (Asa...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi prof., medical physics dept., medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran hassan zarghani ph.d. student of medical physics, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. x-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. these effects obey the lnt hypothesis that occur at lo...

Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده ریاضی 1390

this page was created using nitro pdf trial software. to purchase, go to http://www.nitropdf.com/ this page was created using nitro pdf trial software. to purchase, go to http://www.nitropdf.com/ this page was created using nitro pdf trial software. to purchase, go to http://www.nitropdf.com/ this page was created using nitro pdf trial software. to purchase, go to http://www.nitropdf.com...

Journal: :Diagnostic and interventional radiology 2013
Mei Bai Xianghua Liu Bin Liu

PURPOSE We aimed to determine the effective dose given to patients during neuroradiological C-arm computed tomography (CT) procedures. MATERIALS AND METHODS Measurements were performed on 48 patients using a dose-area product (DAP) meter. A PC-based Monte Carlo program (PCXMC, STUK, Helsinki, Finland) was used to calculate the effective dose from the DAP values of each patient. Organ doses we...

2016
Anna Varghese Roshan S. Livingstone Lijo Varghese Parveen Kumar Sirish Chandra Srinath Oommen K. George Paul V. George

Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing a...

Journal: :AJNR. American journal of neuroradiology 2009
C B Nauer F Kellner-Weldon G Von Allmen D Schaller J Gralla

BACKGROUND AND PURPOSE For CT scan planning, scan projection radiographs (SPR) are used. Tube tension and current for head SPR can be reduced to a minimum because of the small head diameter and because only high-contrast structures need to be visualized for planning. The goal of this study was to investigate SPR of the head in respect to effective doses, the influence of dose-reduction measures...

Journal: :Radiation protection dosimetry 2008
O Dragusin M Gewillig W Desmet K Smans L Struelens H Bosmans

Flat-panel X-ray detectors for fluoroscopy represent a modern imaging equipment that is being implemented in paediatric cardiac catheterisation laboratories. Infants and children represent a group of patients with a high radiosensitivity. A survey of 273 (126 diagnostic and 147 therapeutic) paediatric catheterisations was performed to investigate the radiation doses delivered by the new X-ray s...

Journal: :Iranian Journal of Radiology 2021

Context: This review aimed to investigate the computed tomography (CT) imaging features of coronavirus disease 2019 (COVID-19). Evidence Acquisition: Bilateral lung involvement (70%), peripheral distribution (67.5%), multifocal (67.3%) and ground glass opacity (66.1%) were observed in most infected patients. Results: Evaluation number lobes involved patients showed no abnormalities 7.2% (85/117...